Phosphate Ester Fire Resistant Hydraulic Fluid Defoaming: Answers from Field Practice

·February 11, 2026Hydraulic Oil
Phosphate Ester Fire Resistant Hydraulic Fluid Defoaming: Answers from Field Practice

Hey everyone, it’s been a while since our last update. As we kick off the new year, thank you for your patience and unwavering support—your trust is the strongest driving force behind our continued progress. Without further ado, let’s dive into today’s topic: Defoaming Phosphate Ester Fire-Retardant Fluids: On-Site Solutions. We hope this article deepens your understanding of defoaming applications while sparking comprehensive reflection on material fundamentals and standard requirements.

To facilitate understanding, we’ll begin with the origins, industry standards, and classifications of flame-retardant hydraulic fluids. We’ll then progressively dissect the unique characteristics of the phosphate ester subcategory and the multifaceted complexities inherent in its systems.

The Origin and Development of Fire Resistant Hydraulic Fluids

First, regarding its origin, fire resistant hydraulic fluid is essentially hydraulic oil, with the primary distinction being its fire prevention capability. Hydraulic systems are widely adopted in modern machinery due to their compact structure, responsive operation, ease of automation, and high power output. Hydraulic fluid serves as the lifeblood of these systems, primarily transmitting power, lubricating components, dissipating friction heat, flushing contaminants, preventing corrosion, and providing sealing. While mineral-based hydraulic fluids offer numerous advantages, their primary drawback is flammability. When mineral-based hydraulic oil is used in hydraulic systems operating near high-temperature surfaces exceeding 300°C or in environments with open flames, there is a significant risk of fire.

To eliminate fire hazards caused by the use of mineral oil-based hydraulic fluids and to ensure safety, countries worldwide have actively conducted research and development of fire-resistant hydraulic fluids, driven by considerations of disaster prevention, safety, energy efficiency, and cost-effectiveness.

Fire Resistant Hydraulic Fluids

The development of fire-resistant hydraulic fluids began at the end of World War II, with phosphate esters emerging as fire resistant hydraulic fluids, initially used in aircraft hydraulic systems. In civilian industries, they are mainly used in hydraulic systems that are in contact with or near fire or heat sources in industries such as metallurgy, mining, power plants, and mechanical processing. To adapt to the development of modern hydraulic technology, various types of fire-resistant hydraulic fluids (also known as fire-resistant fluids) have been continuously improved and developed.

Classification Standards and Evolution of Fire Resistant Hydraulic Fluids

The naming conventions, system classifications, and performance focuses under different standards are not entirely the same. The following section will begin by comparing and summarizing the classification methods of mainstream flame-retardant hydraulic fluids using two commonly used standards: ISO 6743-4 and ISO 12922.

Classification of Fire Rsistant Hydraulic Fluids Under ISO Standards

Regarding standards, as a critical industrial safety material, fire-resistant hydraulic fluids are subject to multiple classification criteria covering diverse performance metrics and application domains. Without a clear overview of these standards, one might easily become confused. Based on the international classification ISO 6743-4 and the ISO 12922 hydraulic fluid specifications, fire resistant hydraulic fluids are summarized as follows:

Fire Resistant Hydraulic Fluid

Classification Guide for Different Types of Fire Resistant Hydraulic Fluids

Based on two criteria, fire resistant hydraulic fluids are primarily categorized into HFAE (water-in-oil emulsion), HFAS (high-water-base fluid), HFB (oil-in-water emulsion), HFC (water-containing polymer solution), HFDR (phosphate ester synthetic fluid), and HFDU (other waterless synthetic fluids). Below is a list of their respective application ranges:

CategoryNameTypical Moisture ContentOperating TemperatureTypical ProductsTypical Applications
HFAEWater-in-oil emulsion95%5~50°CEmulsifiable Oil-Based Hydraulic Support Fluid
Coal Mines
HFASHigh water-based fluid95%5~50°CFully Synthetic Hydraulic Support Fluid
Metalworking Fluid
Coal Mine Metal Processing
HFBOil-in-water emulsion40%5~50°CMicroemulsion Hydraulic Support Fluid for Metallurgical IndustryCoal Mine Hydraulic Fluids
HFCAqueous polymer solution35%-25~50°CWater-Glycol Fire Resistant Hydraulic FluidCoal Mine Steel and Shipbuilding
HFDRPhosphate ester fire-resistant hydraulic fluid0-20~50°C
150°C Short-term
Phosphate Ester Fire Resistant Hydraulic FluidAviation, Power Generation
HFDUSynthetic fluid (non-phosphate ester)0-20~50°C
150°C Short-term
Polyol Ester Fire Resistant Hydraulic FluidCoal Mines, Steel

Standard Version Changes and Phase-out of Chlorinated Hydrocarbon Fire Retardants

It’s worth noting that I didn’t see HFDS (chlorinated hydrocarbons) and HFDT (a mixture of chlorinated hydrocarbons and phosphate esters) listed in the two standards above. I later investigated another standard.

These two products existed in ISO 6743-4-1982, but were completely removed in ISO 6743-4-1999.

This raises a thought-provoking point: in the long history of industry and commerce, products and standards are not absolute; they generally follow the pattern of “continuous iteration and compliance evolution.”

It’s important to understand that before the 1980s, chlorinated hydrocarbon fire-retardant hydraulic fluids could be used as long as fires caused by mineral hydraulic fluids could be effectively prevented. However, with the introduction of relevant environmental regulations (such as REACH), increased environmental awareness, and the emergence of ISO 15380 (an environmentally acceptable hydraulic fluid standard), it was discovered that chlorinated hydrocarbons themselves may not be directly flammable.

However, it undergoes a pyrolysis reaction when exposed to high temperatures or open flames, producing extremely dangerous byproducts such as carbonyl chloride and hydrogen chloride, which can easily lead to secondary poisoning. Furthermore, it accumulates in living organisms, pollutes the environment, and can form hydrochloric acid upon absorbing water, corroding equipment and components. Therefore, this type of product has been gradually phased out, or its use has been restricted. In short, although it is difficult to ignite, it is not safe.

ISO 6743-4-1982 Classification of Flame-Retardant Hydraulic Fluids

ISO 6743-4-1982 Classification of Flame-Retardant Hydraulic Fluids

ISO 6743-4-1999 Classification of Flame-Retardant Hydraulic Fluids

ISO 6743-4-1999 Classification of Flame-Retardant Hydraulic Fluids

Supplementary Notes on Silicone Oil and Other Special Non-Flammable Hydraulic Fluids

To add to this, special flame-retardant hydraulic fluids also include silicone oils, with viscosities ranging from 0.65 to 30,000 mm²/s. However, due to their poor adhesion to metal surfaces, their rust-preventive effect is not good, and their high coefficient of boundary friction leads to significant equipment wear.

Despite this, organosilicon, with its extremely low pour point and high ignition point, exhibits unique advantages in extremely low to high temperature environments (-55~260℃). Furthermore, continuous improvements in synthesis processes and alkyl modification processes have enhanced the adsorption and lubrication properties of organosilicon. The low-friction characteristics of ether-based oils have also been further optimized.

The performance of these two types of materials is gradually improving, and their application in the field of industrial flame-retardant hydraulic fluids is becoming increasingly widespread and mature. Those interested can explore this further.

Based on the fire hazards and chemical composition of hydraulic fluids, a summary classification can be presented as shown in the diagram below.

Fire Hazard of Hydraulic Fluids, Chemical Composition

A Multi-Dimensional Classification Perspective of Fire Resistant Hydraulic Fluids

Therefore, flame-retardant hydraulic fluids constitute a broad category that can be subdivided into several major classes based on different classification criteria. From a composition perspective, they can be categorized into water-based (water-in-oil, oil-in-water, true solutions), ether-based (polyether, allyl ether), synthetic ester-based (fatty acid esters, polyol esters), and phosphate ester-based types. These exhibit significant differences in chemical composition, stability, lubricity, and adaptability.

From a temperature perspective, they can be categorized as ambient, medium-temperature, and extreme-temperature types. At the industry level, they are further divided into industrial applications, power generation applications, mining applications, aviation applications, and other fields.

When these categories intertwine, they weave a vast, tangled web that leaves us feeling lost, prompting a barrage of questions we struggle to answer, such as:

Example 1: “What additives are used in fire resistant hydraulic fluids?” Whoa… that’s a huge topic. Can we narrow it down? Dig deeper? Specifically… which type? Which industry? Which application? Which system…?

Example 2: “Which defoamer should be used for fire resistant hydraulic fluid?” Hold on… this is a topic deep enough to fill dozens of doctoral theses… It’s like asking, “What medicine should I take when I feel unwell?” We need to break this down, dissect it, and get deeper and more specific. Specifically… which industry scenario? Which chemical system? Which “system constraints”? Which type of “foaming pain points”…

TypesNameTypical Moisture ContentOperating TemperatureTest Temperature °CFoaming Tendency/sTability (ml/ml)Testing Standards
HFAEWater-in-oil emulsion95%5~50℃25300/10ISO6247
50300/10
25300/10
HFASHigh-water-base liquid95%5~50℃25300/10ISO6247
50300/10
25300/10
HFBOil-in-water emulsion40%5~50℃25——ISO6247
50——
25——
HFCAqueous polymer solution35%-20~50℃25300/10ISO6247
50300/10
25300/10
HFDRPhosphate ester flame-retardant hydraulic fluid0-20~70°C 150°C (short term)25300/10ISO6247
93300/10
25300/10
HFDUSynthetic fluid (non-phosphate ester)0-20~70°C 150°C (short term)25300/10ISO6247
93300/10
25300/10

The above figure summarizes the foaming requirements for several fire resistant hydraulic fluids in the ISO 12922 standard. At first glance, it seems that the referenced standards are the same, and the data on foaming tendency and stability requirements are basically the same (except for HFB). It’s easy to get the impression that the types of defoamers used should be universal, right? Actually, we’ve been led into a “dream” that’s been “woven” together. Let’s think about it together:

1. “Water-based Schools”: HFAE, HFAS, HFC

We group these three substances together because their underlying chemical logic involves a large amount of water. In highly concentrated systems where water is the continuous phase, the defoamer maintains a critical state of “seemingly soluble but not quite soluble.” Ordinary silicone oil cannot penetrate the aqueous phase and will float directly on the surface, forming a layer of oil film that appears “colorful.” In severe cases, this can cause sensor malfunction. Furthermore, microorganisms easily proliferate in aqueous systems, and the stability of the defoamer is greatly affected by pH. Initial dosages are generally large, and the defoaming component should primarily consist of organosilicon polyethers or specially modified siloxanes.

2. “Phosphate Ester School”: HFDR

This substance appears to be a lone wolf in the list above. Phosphate esters are inherently highly polar solvents, making them extremely effective at dissolving ordinary defoamers. Ordinary defoamers dissolve completely upon contact, becoming part of the solution. Once the defoamer is “dissolved,” it loses its ability to break up bubbles. It might, with a sincere “desperate intent,” inadvertently create an outstanding “foaming business.” This isn’t surprising; defoaming with this type of substance generally requires highly polar, specialized defoamers or special fluorinated compound formulations.

3. “Synthetic Ester School”: HFDU

These substances contain no water and exhibit properties intermediate between mineral oils and phosphates. They require defoamers capable of withstanding short-term temperatures up to 150°C. Misusing water-based defoamers will cause them to carbonize, fail, or even form deposits at high temperatures. Defoaming these substances typically requires polyacrylates, short-chain modified organosilicones, or polyol-based compounds as primary agents.

On-Site Case Study of Defoaming Waterless Phosphate Ester Fire-Retardant Hydraulic Fluid at a Power Plant

Okay, let’s conclude today’s topic with an application case. Evisco has a client who primarily supplies anhydrous phosphate ester flame-retardant hydraulic fluids to power plants. More specifically, they supply No. 46 phosphate ester flame-retardant hydraulic fluid.

Thanks to years of experience and technical expertise, their work has been progressing well. Recently, however, they’ve been facing a major headache. During the power plant’s periodic inspections, everything else passes except for one crucial element: foam. No matter what they do, they can’t pass. It’s important to know that the standard for testing anhydrous phosphate ester fluids in power plants is DL T 571-2024. Its foam requirements are more stringent than those of the ISO 12922 standard.

TypesNameProduct StandardsOperating TemperatureTest Temperature °CFoaming Tendency/sTability (ml/ml)Testing Standards
HFDRPhosphate Ester Fire-Retardant Hydraulic FluidIS0 12922-2020-20~70°C 150°C (short term)25300/101S06247
93300/10
25300/10
HFDRPhosphate Ester Fire-Retardant Hydraulic FluidDLT 571-2024-20~70°C 150°C (short term)24200/0GB/T 12579
93.540/0
24200/0

To resolve this issue, the client searched extensively within and outside the industry for various defoamers, adding them to their existing phosphate ester fire resistant hydraulic fluid units in varying amounts and appearances—colorless, transparent, translucent, and milky white. This led to two conflicting test results: some defoamers showed no effect initially, while others, especially the milky white products, initially showed improvement, but by the next scheduled test, the data was consistently substandard.

When they contacted our company, their system had become quite complex. There wasn’t a perfect solution; firstly, we had to intervene, and secondly, we were verifying our initial assumptions. Perhaps we could consider the problem from two perspectives:

  1. System Compatibility

As previously noted, the phosphate ester system itself is a highly polar solvent, rendering many defoamers ineffective when added. They either dissolve directly or fail to achieve compatibility.

Customer feedback indicates that milky-white products perform relatively better. It may be worth considering the incorporation of silica powder. After several days of experimentation with a blend of modified silica, silica powder, emulsifiers, and dispersants, the results measured under laboratory conditions were quite promising. Moreover, after several days of standing, the data remained perfect upon re-testing. It feels like we stumbled upon the solution, possibly hitting the core of the problem.

  1. Appropriate Dosage of Defoamer.

This is a difficult question to answer definitively. For example, how many ppm of dimethyl silicone oil can 150SN base oil dissolve at three temperatures: 24℃, 93.5℃, and a further 24℃? And at each temperature, does it achieve good defoaming and foam-suppressing ability?

Objectively speaking, there is no authoritative data available in academic journals or publicly available literature. The internal composition of each batch of oil (the proportions of normal, isomers, and cycloalkylalkanes) varies, resulting in different solubilization rates for dimethyl silicone oil.

Furthermore, even slight imperfections in oil processing, or under polar conditions, can lead to unstable long-term distribution and agglomeration, and sedimentation. Similarly, determining the appropriate dosage requires a stepwise experiment to arrive at an optimal application conclusion.

Following the completion of the above two tasks, the data measured under laboratory conditions proved reliable. Even after being left in natural conditions for several dozen days, the results remained satisfactory. Subsequently, in consultation with the client, additional samples were collected from operational units that had been in use for longer periods and exhibited more pronounced discoloration. These samples were retested, and the data obtained were found to be consistent and valid.

After obtaining preliminary positive results for the product, we provided the customer with a drum of defoamer. However, two months later, the customer reported that their equipment’s routine inspection data failed to meet standards. This left us completely baffled—where could the problem have originated?

Foam PropertiesProgram I, 24°C510/480mL/mLGB/T 12579-2002
Program II, 93.5°C740/540mL/mL
Program III, subsequent 24°C550/530mL/mL

The data shows that the foaming data is quite poor. Excluding the problem of defoamer gelation caused by high moisture content, the particle size data is normal, and the acid value data is slightly excessive (above 0.15 in DL/T 571-2024 standard). It is still a problem of extremely abnormal foaming data. Combining the previous product formula and customer feedback, the internal system of the unit at the power plant site is equipped with 1μm ion exchange resin and an activated filter, both of which are randomly installed. After the defoamer is added, it must withstand repeated filtration for half a month to a month before regular testing is carried out.

Test ItemsResults DataUnitTesting Method
Kinematic Viscosity (40°C)44.57m㎡/sNB/SH/T 0870-2020
Density (20°C)1.1489g/cm3SH/T 0604-2000
Pour Point-18℃GB/T3535-2006
Acid Value (as KOH)0.18mg/gGB/T 7304-2014
Moisture135mg/kgGB/T11133-2015
Chlorine Content<1mg/kgASTM D7536-24
Volume Resistivity (20°C)2.1×10 to the power of 7Ω·mDL/T 421-2009
Autoignition Temperatures555℃DL/T 706-2017
Flash Point (Open Cup)260.0℃GB/T 3536-2008
Foam PropertiesProgram I, 24°C510/480mL/mLGB/T12579-2002
Program II, 93.5°C740/540mL/mL
Program III, followed by 24°C550/530mL/mL
Particle Contamination LevelParticle count (5–15 μm)650pcs/100mLDL/T432-2018
Particle count (15–25 μm)93pcs/100mL
Particle count (25–50 μm)13pcs/100mL
Particle count (50–100 μm)13pcs/100mL
Particle count (>100 μm)0pcs/100mL
Particle Contamination Level (NAS 1638)4——NAS 1638-2011

After receiving the above feedback, the formula was adjusted again in the laboratory. The approach was changed to a simple, non-particle-free, highly polar solvent compound. Repeated tests were conducted, and the defoaming effect, after continuous exploration, was basically consistent with the data obtained under the same dosage conditions.

Conclusion

To date, Evisco has been constantly chasing our clients for regular testing results, wanting to validate our approach and learn from this experience that static data from the lab can never replace the absolute stability of real-world testing. Faced with precise 1μm filtration and high-standard polarity challenges, defoamers must undergo a qualitative leap from “physical dispersion” to “molecular-level compatibility” to truly “survive” in phosphate ester systems. Previously, we focused on passing tests; now we’re relentlessly pursuing real-world survival. Before, clients chased formulas; now we chase answers on-site. Because only by respecting the real-world environment can we surpass standards. Research and development is a never-ending journey…

Table of Contents

Recent Posts

August 3, 2026

Best Practices for Industrial Lubricant Maintenance and Storage

Practical guide to lubricant maintenance: data, examples, and a decision rule.

July 1, 2026

Eaton E-FDGN-TB004-E / Vickers 35VQ25: Why OEMs Test Hydraulic Oil So Hard

Eaton (formerly Vickers) is one of the most demanding hydraulic pump OEMs in the world, and their pump test specifications have become the de facto global

June 30, 2026

ISO 6743 Lubricant Family Codes: The Hidden Language of Industrial Lubricant Specifications

ISO 6743 is the international standard for classifying industrial lubricants and related products, and it is the most comprehensive classification system